Bradford-White Corp M-2-XR75S Water Heater User Manual


 
Residential Extra Recovery Series (XR)
Energy Saver Gas Water Heater
The XR Atmospheric Vent FVIR Defender Safety System
®
Models Feature
(Except M-2-XR75S):
Advanced ScreenLok
®
Technology Flame Arrestor Design—Flame
arrestor is designed to prevent ignition of flammable vapor outside of the water
heater.
Resettable Thermal Switch—Proven and reliable bimetallic switch prevents
burner and pilot operation in case of ongoing flammable vapor burn inside of
the combustion chamber or restricted air flow.
Piezo Igniter—Easy and quick lighting of the pilot burner by push button.
Pedestal Base—Rugged and durable base allows easy transport, positioning
and pr
ovides corrosion resistant contact with floor.
Maintenance Fr
ee—
No r
egular cleaning of air inlet openings or flame arrestor
is required under normal conditions.
Sight Window—Offers a view into the combustion chamber to observe the
operation of the pilot and burner.
All XR Models Feature:
Factory Installed Hydrojet
®
Total Performance System—Cold water inlet
sediment reducing device helps prevent sediment build up in tank. Increases
first hour delivery of hot water while minimizing temperature build up in tank.
Vitraglas
®
Lining—Bradford White water heater tanks are protected from the
corrosive effects of hot water by an exclusive ceramic porcelain-like coating.
The Bradford White high silica Vitraglas
®
lining provides a tough interior surface
for our hot water tanks.
Fully Automatic Controls—Built-in energy cut-off switch prevents
abnormally high water temperature for extra safety. Built-in gas pressure
regulation.
Side Connections—3/4" NPT tappings allow easy connections for space
heating applications (potable water only).
2" Non-CFC Foam Insulation—Surrounds the tank surface, saving energy
by retarding loss of heat (M-1 models have 1" of insulation).
Water Connections—3⁄4" NPT factory installed true dielectric fittings extend
water heater life and eases installation (M-2-XR75S has 1" NPT dielectric
waterway fittings).
Factory Installed Heat Traps—Design incorporates a flexible disk that
reduces heat loss in piping and eliminates the potential for noise generation
(Except M-2-XR75S).
Protective Magnesium Anode Rod—Provides added protection against
corrosion for long trouble-free service.
3x4 “Snap Lock” Draft Diverter—Allows either 3" or 4" vent connections
with inputs of 40,000 BTU/Hr. or less. Over 40,000 BTU/Hr. has the 4" “Snap
Lock” Draft Diver
ter.
Flue Baffle—Maximizes the amount of heat absorbed by the tank and
reduces heat loss during standby periods.
Steel Tank—Heavy gauge steel automatically formed, rolled and welded.
T&P Relief Valve—Included.
Brass Drain Valve.
Design Certified by CSA International (formerly AGA/CGA).
6 or 10-Y
ear Limited Tank Warranties / 6-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the war
ranty included with the heater
.
Photo is of
M-2-XR65T6FBN
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 7,063,133 B2; 5,954,492; 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185;
5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968;
4,672,919; Re. 34,534. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105.
Defender Safety System
®
, ScreenLok
®
, Vitraglas
®
and Hydrojet
®
are registered trademarks of Bradford White
®
Corporation.
109-B-0807-A
Bradford White received the highest numerical score among water heater/boiler manufacturers in the proprietary J.D. Power and Associates/ McGraw-Hill Construction 2006 HVAC and Water Heater/Boiler Subcontractor Satisfaction Study
SM
.
Study based on 882 r
esponses measuring 3 water heater/boiler manufactur
ers and measur
es opinions of subcontractors. Pr
oprietar
ystudy r
esults are based on experiences and perceptions of subcontractors surveyed in May through July 2006. Your
experiences may vary. Visit jdpower.com
"Highest in Subcontractor Satisfaction among Water Heater/Boiler Manufacturers"