Bosch Appliances 2400E NG Water Heater User Manual


 
6 720 608 263
16
Appliance details
FOR NATURAL GAS
Maximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and a Pressure drop
of 0.3 in Water Column (0.75mbar).(Based on a 0.60 Specific Gravity Gas) Btu numbers given in thousands.
Fig. 22
Follow boxed numbers for piping just one 2400 E (example: ¾” B.I. Natural Gas pipe for 20 ft (6.1m). will
handle 190,000 btu’s (55.7 kWh). For multiple appliances combine the total btu input load and then refer to
applicable chart below.
Maximum Capacity of Semi-Rigid (flexible, non
corrugated) Tubing in Thousands of BTU per Hour of
Undiluted Liquefied Petroleum Gases (at 11 inches
Water Column Inlet Pressure).
(Based on a Pressure Drop of 0.5 Inch Water Column)
* Source National Fuel Gas Code NFPA 54, ANSI
Z223.1 - No Additional Allowance is necessary for an
ordinary number of fittings
FOR LP GAS
Maximum Capacity of Pipe in Thousands of BTU per Hour of Undiluted Petroleum Gases (at 11 inches Water Column Inlet
Pressure) (Based on a Pressure Drop of 0.5 Inch Water Column).
* EHD = Equivalent Hydraulic Diameter. The greater the
value of EHD, the greater the gas capacity of the tubing
.
Copper
Outside Length of Tubing, Feet
diameter
Inch 10 20 30 40 50 60 70 80 90 100
3/8 39 26 21 19 _ _____
1/2 9262 5041 37 3531292726
5/8 199 131 107 90 79 72 67 62 59 55
3/4 329 216 181 145 131 121 112 104 95 90
Nominal
Iron
Length of Black Iron Pipe, Feet
Pipe Internal
Size, Diameter
inches inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200
1/4 0.364 32 22 18 15 14 12 11 11 10 9 8 8 7 6
3/8 0.493 72 49 40 34 30 27 25 23 22 21 18 17 15 14
1/2 0.622 132 92 73 63 56 50 46 43 40 38 34 31 28 26
3/4 0.824 278 190 152 130 115 105 96 90 84 79 72 64 59 55
1 1.049 520 350 285 245 215 195 180 170 160 150 130 120 110 100
1 1/4 1.380 1050 730 590 500 440 400 370 350 320 305 275 250 225 210
1 1/2 1.610 1600 1100 890 760 670 610 560 530 490 460 410 380 350 320
2 2.067 3050 2100 1650 1450 1270 1150 1050 990 930 870 780 710 650 610
Nominal
Iron Pipe
Black Iron Pipe
Size, Length of Pipe, Feet
Inches 10 20 30 40 50 60 70 80 90 100 125 150
1/2 275 189 152 129 114 103 96 89 83 78 69 63
3/4 567 693 315 267 237 217 196 185 173 162 146 132
1 107 732 590 504 448 409 378 346 322 307 275 252
1 1/4 220 149 121 103 913 834 771 724 677 630 567 511
1 1/2 330 229 185 155 141 127 118 108 102 976 866 787
* EHD = Equivalent Hydraulic Diameter. The greater the
value of EHD, the greater the gas capacity of the tubing.
Tube
size,
inches EHD*
10 20 30 40 50 60
1/2 18 EHD 82 58 47 41 37 34
3/4 23 EHD 161 116 96 83 75 68
1 30 EHD 330 231 188 162 144 131
1 1/4 37 EHD 639 456 374 325 292 267
Length of Flexible Corrugated Stainless Steel Tubing (CSST), Feet
Tube
size
inches EHD*
10 20 30 40 50 60
1/2 18 EH
D
129 91 74 64 58 53
3/4 23 EH
D
254 183 151 131 118 107
130 EH
D
521 365 297 256 227 207
1 1/4 37 EH
D
971 661 528 449 397 359
Length of Flexible Corrugated Stainless Steel Tubing (CSST), Feet