Bosch Appliances 600 Water Heater User Manual


 
BISN0047.0 26/06/2007 Page 3
Characteristic Data
Pilot orifice diameter (mm) NG 0.30
LPG 0.19
TG 0.56
TLP 0.56
Burner injector diameter (mm) NG 1.20
LPG 0.75
TG 2.15
TLP 2.15
Burner pressure ( kPa ) NG 0.87
LPG 2.60
TG 0.40
TLP 0.40
Water flow selector at left hand stop.
Maximum water flow 10 litres / minute
Temperature rise 25°C
Minimum inlet pressure NG 90 kPa
( 9.0 metres W.G.)
LP 55 kPa
( 5.5 metres W.G.)
Water flow selector at right hand stop
Minimum water flow 4.5 litres / minute
Temperature rise 55°C
Minimum inlet pressure NG 30 kPa
( 3 metres W.G. )
LP 10 kPa
( 1 metre W.G. )
Refer to rating label located on the bottom right hand corner of the back panel for additional
data.
Freezing
Weather
In areas where the atmospheric temperature may drop below 0°C,
the heater must be drained to prevent damage by expansion of freezing
water. For appliances installed in locations where the temperature falls
below 0° C for brief periods , the installation of an EXOGEL expansion
valve, (part number H 707 060 151), will minimise the possibility of damage
to the appliance.
This water heater MUST NOT be installed in areas where the
temperature remains below 0°C for extended periods.
Conversion and Spare Parts
For spare parts or conversion of the heater to operate on a different gas that for which it was
originally manufactured, please contact your local gas authority, authorised service agent or
the manufacturer
Exogel
Hot Water
1 Metre
minimum