Bosch Appliances 19/24CBI Boiler User Manual


 
9/14, 14/19 & 19/24CBi
USER INSTRUCTIONS &
CUSTOMER CARE GUIDE
134
Central Heating
When a demand is made for heating by the system controls
(i.e. a programmer or room thermostat). A pump will energise
circulating primary water around the heating system and the burner,
after a few seconds, will light. The heat output from the appliance in
this mode has been factory set to give maximum output or as reset by
your installer. The appliance will operate as necessary to maintain the
temperature of the radiators at the level set by the adjustment of the
boiler Temperature Control Knob. (See Fig. 1.)
If the system no longer requires output to maintain the desired
room temperature, the burner will extinguish. The pump and fan will
continue to run for a short period to dissipate the residual heat from
the appliance and then switch off.
The appliance will supply heat to the central heating system as
required.
Hot Water
The appliance operates to supply only domestic hot water when
the heating temperature mode is fully anti-clockwise, at the 0 position
or the timer is programmed to OFF mode.
IMPORTANT: THIS APPLIANCE IS FOR USE WITH NATURAL GAS AND LPG
THESE INSTRUCTIONS APPLY IN THE UK ONLY.
THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE GAS METER
GUARANTEE
REGISTRATION
You should complete and return the postpaid Guarantee
Registration Card within 30 days of purchase.
The card will register you as the owner of your new
Worcester boiler and, while this will not affect your statutory
rights in any way, it will assist us to maintain an effective and
efficient customer service by establishing a reference and
permanent record for your boiler.
IMPORTANT: SERIAL NUMBER. Copy the number off the
Guarantee Card.
FOR YOUR OWN RECORD
MODEL
SERIAL NUMBER
(See identity label inside appliance casing)
TYPE/SIZE DATE OF INSTALLATION
MAINTAINING YOUR
APPLIANCE
Your new Worcester boiler represents a long-term
investment in a reliable, high quality product.
In order to realise its maximum working life, and to ensure
it continues to operate at peak efficiency and performance, it is
essential that your boiler receives regular, competent servicing
and annual maintenance checks beyond the initial 12 month
guarantee period.
Regular service contracts can be arranged with your installer
– however if you have difficulty making a satisfactory
arrangement simply contact Worcester on 08457 256206 for
help.
If you would like to know more about Worcester’s extended
warranty options please tick the appropriate box on your
warranty registration card.
G. C. NUMBERS
APPLIANCE NATURAL GAS LPG
9/14CBi 41 311 50 41 311 51
14/19CBi 41 311 52 41 311 53
19/24CBi 41 311 54 41 311 55
8 716 103 191b 10/05
Worcester, Bosch Group, Cotswold Way, Warndon, Worcester WR4 9SW.
Telephone: 01905 754624 Fax: 01905 753130.
Technical Helpline 08705 266241.
Worcester, Bosch Group is a trading name of BBT Thermotechnology UK Limited
www.worcester-bosch.co.uk
Worcester supports the
Benchmark code of practice
Vote for your
‘Installer of the year’ at
www.worcester-bosch.co.uk
CORGI CONTACT
All CORGI Registered installers carry a CORGI ID card and
have a registration number. Both should be recorded in your
central heating log book
. You can check your installer is
CORGI Registered by calling CORGI on 01256 372300