Bionaire BCM5521 Humidifier User Manual


 
Digital COOL MIST
Humidifier with
Permanent Filter
MODEL BCM5521
Filter: BWF100-P
Read instructions before operating.
Retain for future reference.
Instruction Leaflet
INFO-LINE
If after having read this leaflet, you have any
questions or comments on your air humidifier,
call 1-800-253-2764 in North America.
9100030003929
WEEKLY MAINTENANCE
Remove Scale:
1. Repeat steps 1-4 above.
2. Clean the base by partially filling the base with one 8-oz
cup of undiluted white vinegar, or use Clean-Away™ by
Bionaire
®
. Let solution stand 20 minutes, cleaning all
interior surfaces with a soft brush. Dampen a cloth with
undiluted white vinegar and wipe out entire base to
remove scale.
3. Rinse with clean warm water to remove scale and the
white vinegar solution before beginning to disinfect the
reservoir.
DISINFECT HUMIDIFIER BASE AND RESERVOIR
1. Fill humidifier base with 1/4 gallon of water and 1/2
teaspoon of chlorine bleach.
2. Fill the reservoir 1/2 full with water and 1/2 teaspoon of
chlorine bleach.
3. Let the solution stand for 20 minutes, swishing every
few minutes. Wet all surfaces.
4. Carefully empty the base and reservoir after 20 minutes,
and rinse with water until you cannot detect any bleach
smell. Dry with a clean cloth or paper towel.
5. Check the Filter Monitor to see if it is time to replace
the filters. Depending on water hardness in your area, it
may be necessary to change the filter every 1-2
months. Re-insert the wick filters into the wick frame.
6. Refill the water tank as directed with cool tap water,
replace the humidifier housing, and turn the unit on.
STORAGE INSTRUCTIONS
If your humidifier will not be in use for two days or more,
or at the end of the season follow these instructions.
1. Clean and dry the humidifier thoroughly as per the
“Weekly Maintenance” instructions.
2. Let the humidifier dry completely before storing. Do not
store with water inside the base or water reservoir.
3. Remove the reservoir cap. Do not store with the reservoir
cap in place.
4. Throw away the wick filters. Do not leave wick filters
inside the humidifier.
5. Store in a cool dry location.
6. Order your new filters so they will be ready for next season.
SERVICE INSTRUCTIONS
1. Do NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void the
warranty. The inside of the unit contains no user serv-
iceable parts. All servicing should be performed by
qualified personnel only.
2. If you need to exchange the unit, please return it in its
original carton, with a sales receipt, to the store where
you purchased it. If you are returning the unit more than
30 days after the date of purchase, please see the
enclosed warranty.
3. Should your humidifier require service, please call
1-800-253-2764 in North America for further assistance.
4. If you have any other questions or comments, feel free
to write to us or visit our website www.bionaire.com
Bionaire
JCS/THG, LLC
303 Nelson Avenue
Neosho, MO 64850
Troubleshooting for your Cool Mist Humidifier
Trouble
LED not illuminated.
Mist output minimal to
none.
•Water leaks from water
reservoir.
•Water Filter turns brown.
•Film on water reservoir.
•Water cloudy.
Humidistat cycles on/off.
•Very tight reservoir cap.
Pr
obable Cause
Unit not plugged in.
Power failure.
Filter has not
absorbed water.
Mineral buildup in base.
Humidistat is set too low.
Permanent Filter needs
to be replaced.
Normal operation.
Rubber O-ring is missing
or improperly placed.
Reservoir Cap not
tight enough.
Your filter needs
to be cleaned.
In areas with particular
hard water your wick
filter will need to be
changed frequently.
Mineral deposits cause
film on tank to build up.
Filter needs to
be washed.
Using warm water
to refill reservoir.
Humidifier is reacting
to room humidity level.
Over tightened.
Solution
Plug in unit.
Check circuit breaker or
outlet.
Wait 15 minutes before
starting humidifier.
Regular cleaning of tray
after each use will help
keep the unit functioning
properly.
Set the humidistat to
high.
Replace your wick filter
(BWF100-P) by calling
1-800-253-2764, or visit
www.bionaire.com.
Mist is invisible.
Check to see if inlet or
outlet grills are blocked.
Remove reservoir
cap then replace
or reposition ring.
Tighten the
reservoir cap.
Follow filter cleaning
instructions located in
this manual.
Use Clean-Away™
Solution (DMS216), to
order call 1-800-253-2764,
or visit www.bioaire.com.
Follow filter cleaning
instructions located in
this manual.
.
Refill using cool water.
Set the humidistat to a
higher or lower setting.
Add liquid soap or
petroleum jelly to cap
gasket to ease opening.
Fig. 5
Frequently Asked Questions
Question
What are the variables that
affect run time?
How do I remove film on
water tank?
How can I extend the run
time?
Answer
The estimated run time for this humidifier is based on aver
age room conditions. The actual run time of your humidifier
is dependent on numerous variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifier is placed.
Movement of occupants and the opening and closing of
doors in the room where the humidifier is placed.
Home furnishings in the room where the humidifier is placed.
See Daily Maintenance instructions. Regular cleaning is
recommended.
Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity
level. The unit will turn on and off, which will extend the run
time.
Fill the tank all the way full, place it on the base, let the
water empty into the base until it stops bubbling, then refill
he tank full again. This ensures maximum water capacity
and will extend run time.
Fig. 4
TWO (2) YEARS LIMITED WARRANTY
SAVE THIS WARRANTY INFORMATION
A. This Warranty applies only to the original purchaser of
this product.
B. This Warranty applies ONLY to repair or replacement of
any supplied or manufactured parts of this product that,
upon inspection by JCS/THG, LLC authorized personnel,
is shown to have failed in normal use due to defects in
material or workmanship. JCS/THG, LLC will determine
whether to repair or replace the unit. This Warranty
does not apply to installation expenses.
C. Operating this unit under conditions other than those
recommended or at voltages other than the voltage
indicated on the unit, or attempting to service or modify
the unit, will render this WARRANTY VOID.
D. Unless otherwise proscribed by law, JCS/THG,
LLC shall not be liable for any personal injury,
property or any incidental or consequential dam-
age of any kind resulting from malfunctions,
defects, misuse, improper installation or alteration
of this product.
E. All parts of this product excluding filters, which are
covered under separate warranty, are guaranteed for a
period of 2 years as follows:
1. Within the first 30 days from date of purchase, the
store from which you purchased your product
should replace this product if it is defective in
material or workmanship (provided the store has
in-stock replacement.) If you intend to assert any
claim in connection with the product, please follow
the instructions in paragraph F.
2. Within the first 24 months from date of purchase,
JCS/THG, LLC will repair or replace the product if it
is defective in material or workmanship, subject to
the conditions in paragraph G.
F. If you have any other problem or claim in connection
with this product, please write to our Consumer Service
Department.
G. IMPORTANT RETURN INSTRUCTIONS. Your Warranty
depends on your following these instructions if you are
returning the unit to JCS/THG, LLC:
1. Carefully pack the item in its original carton or other
suitable box to avoid damage in shipping.
2. Before packing your unit for return, be sure to
enclose:
a) Your name, full address with zip code and tele-
phone number
b) A dated sales receipt or PROOF OF PURCHASE,
c) Your $12.50 check for return shipping and han-
dling, and
d) The model number of the unit and the problem
you are having. (Enclose in an envelope and tape
directly to the unit before the box is sealed.)
3. JCS/THG, LLC recommends you ship the package
U.P.S. ground service for tracking purposes.
4. All shipping charges must be prepaid by you.
5. Mark the outside of your package:
Bionaire
JCS/THG, LLC
303 Nelson Avenue
Neosho, MO 64850
SHIPPING AND HANDLING CHARGES: $12.50 (USD)
This Warranty gives you specific legal rights, and you may
have other rights which vary from state to state. The
provisions of this Warranty are in addition to, and not a
modification of, or subtraction from, the statutory
warranties and other rights and remedies contained in any
applicable legislation. To the extent that any provision of
this Warranty is inconsistent with any applicable law, such
provision shall be deemed voided or amended, as
necessary, to comply with such law.
© 2006 JCS/THG, LLC
Bionaire
®
, the Bionaire logo
®
, FilterClean
TM
and Clean-Away
TM
are trademarks of JCS/THG, LLC.
BCM552106EM1 Printed in China