NEW FEATURES IN THE BECKETT R7184 SERIES 5
PRIMARY CONTROLS
Advances in electronics technology are making an exciting impact in our oilheat industry. These developments
have enabled control manufacturers to put high-performance features into residential primary controls.
Since its introduction in 1999, the Beckett R7184 primary control has made advancements and added
features to meet the need of a changing industry. This technical bulletin will discuss some of the new
benefits and wiring improvements to the Beckett R7184 revision 5 primary control.
The operational sequence, interrupted
ignition, limited recycle and reset,
diagnostic LED and communication
port remain consistent on the R7184A,
B, P revision 5 as with the previous
revision.
BENEFITS
• Matching wire colors between components and control will
reduce mistakes during wiring.
• Quick Connects on the lead wires from the burner components
and wire harnesses allow quick component change-out and
reduce the number of leads in the wiring box.
• Data port connection enables reading control characteristics
with Honeywell Diagnostick
™
, QS7100T tester or OnWatch
QuickRead
™
711.
•EnviraC
OM
™
communication terminals have been added for
future networking customization for HVAC systems.
TECHNICAL INFORMATION BULLETIN
APRIL 2004
How to tell the revision level:
The Revision numbers 1, 2 and 3
are located on the label designated
by the number printed on its side.
Revisions 4 and 5 have been
relocated to the side of the primary
control cover. The number also
is
printed on its side.
BECKETT R7184 PRIMARY CONTROL
Series 4
Series 5
Data port
Alarm contacts
EnviraC
OM
™
(3) terminals
or
T- T
(2) terminals
Blue
Violet
Orange
Black
Red
New and relocated features
Component color code
Igniter
Valve
Motor
Line
Limit
Series 5 Control: