Beckett R7184 Burner User Manual


 
NEW FEATURES IN THE BECKETT R7184 SERIES 5
PRIMARY CONTROLS
Advances in electronics technology are making an exciting impact in our oilheat industry. These developments
have enabled control manufacturers to put high-performance features into residential primary controls.
Since its introduction in 1999, the Beckett R7184 primary control has made advancements and added
features to meet the need of a changing industry. This technical bulletin will discuss some of the new
benefits and wiring improvements to the Beckett R7184 revision 5 primary control.
The operational sequence, interrupted
ignition, limited recycle and reset,
diagnostic LED and communication
port remain consistent on the R7184A,
B, P revision 5 as with the previous
revision.
BENEFITS
Matching wire colors between components and control will
reduce mistakes during wiring.
Quick Connects on the lead wires from the burner components
and wire harnesses allow quick component change-out and
reduce the number of leads in the wiring box.
Data port connection enables reading control characteristics
with Honeywell Diagnostick
, QS7100T tester or OnWatch
QuickRead
711.
•EnviraC
OM
communication terminals have been added for
future networking customization for HVAC systems.
TECHNICAL INFORMATION BULLETIN
APRIL 2004
How to tell the revision level:
The Revision numbers 1, 2 and 3
are located on the label designated
by the number printed on its side.
Revisions 4 and 5 have been
relocated to the side of the primary
control cover. The number also
is
printed on its side.
BECKETT R7184 PRIMARY CONTROL
Series 4
Series 5
Data port
Alarm contacts
EnviraC
OM
(3) terminals
or
T- T
(2) terminals
Blue
Violet
Orange
Black
Red
New and relocated features
Component color code
Igniter
Valve
Motor
Line
Limit
Series 5 Control: