BEA XL-DR Home Security System User Manual


 
75.5268.01 20070111 Page 4 of 7
1. DESCRIPTION OF THE INFRARED REMOTE CONTROL
Open the battery compartment at the back of the remote control ;
Insert two AAA batteries supplied with the remote control as shown beside ;
Close the battery compartment.
0-9 Number keys
(1)
Output redirection
(2)
Plus
(3)
Unlock
(4)
Minus
(5)
Holdtime
(6)
Sensitivity
(7)
Detection mode
(8)
Rejection mode
(9)
(10) Not used
(11) Not used
(12) Not used
(13) Not used
(14) Not used
(15) Check Values
(16) Lock
(17) Output configuration
(18) Not used
(19) Setup
(20) Not used
Note: For optimum results point the remote control to the sensor
before pressing its buttons.
2. CONFIGURATION OF THE SENSOR
Every adjustment session using the infrared remote control must start with unlocking and end with a double locking.
The table below lists the parameters able to be adjusted by remote control and the operations required in order to adjust these
parameters.
PARAMETERS ACTIONS LED SIGNAL
UNLOCK
Press the UNLOCK key (4).
Enter your 4-digit access code using 0-9 NUMBER keys (1).
During the first sensor adjustment or if the access code is reset to the "0000" value
(factory setting) or during the first minute after the power-on, press only the UNLOCK key
(4) (no access code required).
UNLOCK with access code
UNLOCK without access code
The red LED flashes quickly waiting for the
access code.
After entering the correct access code or if no
access code is required, the red LED flashes
slowly to indicate that the unlock is successful
and the adjustment session has begun.
Note:
= Adjustment session ON
LOCK
When all the parameters have been set, press the LOCK key (16).
If you wish to enter a new access code, use 0-9 NUMBER
keys (1) to enter the new 4-digit access code within 1 minute.
If no access code is entered or if you want to keep the current access code, press the
LOCK key (16) once more.
If no remote control key is pressed within 1 minute, the adjustment session is automatically
locked.
LOCK with access code change
LOCK without access code or access code change
The red LED stops flashing to return to its normal
function.
CONFIGURATION
WITH REMOTE
CONTROL