BEA Infrared Zone Locator Door User Manual


 
LED COLOR: POSITION
‘ORANGE’ LED FOR POSITION
‘RED’ LED FOR POSITION
‘GREEN’ LED FOR POSITION
SPOTFINDER
USER’S GUIDE
INFRARED ZONE LOCATOR
1 Description & Speci cations
75.0176.04 20080331 Page 1 of 2
BEA’s Infrared (IR) Spot nder is a
hand-held tool used to locate an
active infrared source.
This easily locates an IR area
which can be used to assist in the
palcement of the sensing zone as
well as approximate the distance
from a sensor.
The Spot nder has two settings,
(1) LED only (light, no sound) or
(2) LED and Buzzer.
This accessory will shut-off after
45 seconds of no IR activity. To
reactivate, switch OFF then back
ON by selecting either LED or
BUZZER.
POSITION LED COLOR BUZZER LEVEL IR LIGHT LEVEL
1 GREEN NONE NONE
2 ORANGE SOFT - WEAK LOW
3 RED LOUD - STRONG HIGH
N/A FLASHING ORANGE LOW BATTERIES
2 Settings & Placement
DESCRIPTION SPECIFICATION
POWER SUPPLY AAA Alkaline Batteries (2) Included
DIMENSIONS 3” X 2 1/4” X 1” (76mm x 57mm x 25mm)
MATERIAL ABS Plastic
For sliding door overhead presence detection, place the Spot nder at on the oor so that the IR-SPOT is at the appropriate
distance from the door face. Adjust the IR Curtain on the sensor until the LED turns Orange and/or the Buzzer begins to beep
(as in Position 2 below).
NOTE: The Spot nder only serves to identify an area of infrared light and not necessarily imply the area of the sensors detection.
BEA, Inc. always recommends a walk test to ensure compliance to all applicable standards for sensing patterns.
See ANSI
A156.10 for
Required
Distance