Bard 8403-058 Furnace User Manual


 
Bard Part Number 8403-058 (TH5220D1151)
Setup function Settings & options (factory default in bold)
1
System type
2 Changeover valve
(0/8 terminal)
3 Fan control
(heating)
5 Stage 1 heat cycle
rate (CPH: cycleslhour1*
6 Stage 2 heat cycle
rate/Auxiliary heat
cycle rate (CPH)*
8 Emergency heat cycle
rate (CPH)*
9 Stage 1 compressor
cycle rate (CPH)
10 Stage 2 compressor
cycle rate (CPH)
12 Manual/Auto
changeover
14 Temperature
display
15 Compressor
protection
26 Auxiliary heat control
27 Heat temperature
range stops
28 Cool temperature
range stops
o
1
2
1 heatl1 cool conventional
1 heatl1 cool heat pump (no aux. heat)
Heat only - 2-wire systems, 3-wire zone valves (Series 20), and
normally open zone valves
Heat only with fan
Cool only
2 heat/1 cool heat pump (with aux. heat)
2 heatl2 cool conventional
2 heatl1 cool conventional
1 heatl2 cool conventional
Changeover valve (0/8 terminal energized in cooling)
Changeover valve (0/8 terminal energized in heating)
3
4
5
6
7
8
o
1
o
1
5
1
3
9
Gas or oil furnace - equipment controls fan in heating
Electric furnace - thermostat controls fan in heating
For gas or oil furnaces of less than 90% efficiency
For steam or gravity systems
For hot water systems &furnaces of over 90% efficiency
For electric furnaces
5
1
3
9
9
1
3
5
3
For gas or oil furnaces of less than 90% efficiency
For steam or gravity systems
For hot water systems &furnaces of over 90% efficiency
For electric furnaces
3
For electric emergency heat
For steam or gravity systems
For hot water systems &furnaces of over 90% efficiency
For gas or oil furnaces of less than 90% efficiency
Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
Manual changeover (HeatlCooVOff)
Auto changeover (Heat/Cool/Auto/Off)
Auto changeover only (Auto)
o
1
2
o
1
Fahrenheit
Celsius
No compressor off time
[Other options: 1, 2, 3, 4, or 5-minute offtime]
o
o
1
90
Comfort
Economy
Max. heat temperature setting is 90° F (32° C)
[Other options: 40° F to 89° F (4.5°C to 31.5° C)]
50
Min. cool temperature setting is 50° F (10° C)
[Other options: 51° F to 99° F (10.5° C to 37° C)]
*[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
Patents pending.
69-1935 M.S. 03-06
*
Printed in U.SA on recycled
paper containing at least 10%
post-consumerpaperfibe~.