LISTED SOLID FUEL BURNING APPLIANCE SUITABLE
FOR USE IN RESIDENTIAL, ALCOVE, MOBILE HOME,
OR MASONRY INSERT INSTALLATIONS.
TM
PREVENT HOUSE FIRES - Install and use only in accordance with the Avalon 1190 owner’s manual. Contact your local
building or fire officials about restrictions and installation inspection in your area. Refer to local building codes and the
chimney manufacturer’s instructions for precautions required for passing a chimney through a combustible wall or ceiling.
Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue serving
another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other
means approved by local building or fire officials.
DO NOT REMOVE THIS LABEL
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black or 25 MSG
blued steel connector, with listed (type HT) factory-built chimney, suitable for use with solid fuels or masonry chimney.
Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown below. Pedestal or legs are required.
Maximum alcove depth 48”, minimum alcove height 84”.
MOBILE HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown
below. In addition, mobile home installations require outside air - use the optional pedestal or outside air boot. Pedestal or
legs are required.
DURAVENT model DVL with DURA-PLUS chimney
AMERI-TEC model DCC with model HS chimney
SECURITY model DP with SECURITY model ASHT or S2100 chimney
METALFAB model DW connector with TG chimney
Standard Masonry Chimney with any one of the above listed connectors
MODEL:
Olympic (1190)
TESTED TO RELEVANT PORTIONS OF
UL 1482, 737 AND 907.
SERIAL
NUMBER
FREESTANDING INSTALLATION
CLEARANCES AND
FLOOR PROTECTION
REQUIREMENTS:
A. SIDEWALL TO UNIT
B. BACKWALL TO UNIT
C. CORNER TO UNIT
D. SIDEWALL TO CONNECTOR
E. BACKWALL TO CONNECTOR
F. CORNERWALL TO CONNECTOR
STANDARD RESIDENTIAL
INSTALLATION (SINGLEWALL
CONNECTOR)
16”
15”
9.5”
27.5”
17.5”
20.5”
MOBILE HOME, ALCOVE AND
REDUCED CLEARANCE INSTALLATIONS
(REQUIRES DOUBLE WALL CONNECTOR)
16”
10”
7.5”
27”
12”
18”
STOVE
FLOOR PROTECTOR
6"
MIN.
6" MIN.
16" MIN.
45˚
STOVE
ADJACENT WALL
ADJACENT WALL
F
C
STOVE
BACKWALL
SIDEWALL
E
D
B
A
MINIMUM CLEARANCES TO COMBUSTIBLES:
MANTLE
COMBUSTIBLE SIDE
FACING
COMBUSTIBLE TOP
FACING
FIREPLACE FACING
HEARTH EXTENSION
COMBUSTIBLE SIDEWALL
A
B
C
D
E
F
MASONRY INSERT INSTALLATION
MINIMUM CLEARANCES
TO COMBUSTIBLES AND
HEARTH REQUIREMENTS:
A. SIDEWALL TO INSERT
B. SIDE FACING TO INSERT
C. TOP FACING TO INSERT
WITH MANTLE SHIELD
D. MANTLE TO INSERT
WITH MANTLE SHIELD
*E. HEARTH EXTENSION IN FRONT
F. HEARTH EXTENSION TO SIDES
*NOTE: The Cook Top Model must be installed on a code conforming masonry hearth. If
the fireplace hearth extension is raised 4.5” above a combustible floor, the hearth
extension 16” in front of the fireplace insert must be of non-combustible material and at
least .018” (26 gauge) thick. If the fireplace hearth extension is not raised 4.5”, the hearth
extension 16” in front of the fireplace insert must be constructed of 3.5” thick clay brick or
equivalent. See installation manual for further information.
STANDARD
MODEL
15”
13.5”
30”
17”
32”
19”
16”
8”
COOK TOP
MODEL
15”
13.5”
31”
18”
33”
20”
16”*
8”
REQUIRED EQUIPMENT: Surround Panels
DO NOT remove firebricks or mortar from masonry fireplace.
OPTIONAL EQUIPMENT: Front or rear blower (electrical rating:
115V, 60 Hz., 1.8 Amps)
Replace glass only with AVALON supplied NEOCERAM ceramic
glass (5mm).
Report #028-S-27-2 (June, 1999)
1999 2000 2001 Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec.
For use with solid wood fuels only (cord wood). Operate with
feed door closed - open to feed fire only. Do not use a grate
or elevate fire - build fire directly on the hearth.
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with July 1990 particulate emission standards.
DATE OF MANUFACTURE
Manufactured by: