Aube Technologies TH114 Thermostat User Manual


 
TH114
User s Guide
Non-programmable Thermostat
TH114
400-114-000-B 21/2/05 1/2
Aube’s TH114 Series non-programmable thermostats can be used
to control ambient or floor temperature. The following models are
available:
Each thermostat consists of a control module which must be
mounted on a PB112 Series power base. For the selection and
installation of the power base, refer to its installation instructions.
The DIP switches are located at
the back of the control module.
2.1 Temperature Display (S1)
To switch between °C and °F.
2.2 Model (S2)
Note: Available on certain models only
n Refer to the installation instructions of the
power base.
o Insert the tabs at the top of the control
module in the slots at the top of the
power base.
p Secure the control module using the cap-
tive screw underneath the base.
Note: Do not obstruct the thermostat's vents.
As soon as the thermostat is powered, it undergoes a
series of tests before displaying the actual tempera-
ture.
The measured temperature is below 0°C (32°F). Heat-
ing is turned On.
The measured temperature is above 50°C (122°F) (A
or AF model) or 60°C (140°F) (F model).
The floor sensor is defective or not properly connected
(F model only), or the thermostat is defective.
Note: This procedure must be performed if the thermostat is
mounted on a GFCI-equipped power base.
Test the GFCI immediately after installing
the control module, and once a month there-
after.
n Raise the temperature until the heat-
ing power indicator appears.
o Press the Test button.
p If the test is successful, you will hear a
click caused by the GFCI relay tripping.
The heating power indicator will disap-
pear, GFI will appear and the Fault light
will illuminate. Reset the thermostat by
switching it to Standby and back to On.
q If the test has failed, cut power to the heating system from the
main electrical panel and call customer service.
Note: If the Fault light is On during normal operation, cut power to
heating system at the main electrical panel and have an electrician
verify the installation.
1. Description
A model: controls and displays the ambient temperature
F model: controls and displays the floor temperature
uses an external temperature sensor
AF model: controls and displays the ambient temperature
maintains the floor temperature within desired
limits
uses an external temperature sensor
2. DIP Switch Configuration
F: To select the F model
AF: To select the A or AF model
1 to 24%
25 to 49%
50 to 74%
75 to 99%
100%
GFCI test button * /
Backlight button *
Temperature
adjustment button
On/Standby button
Power output
Actual or setpoint
temperature
Arrow appears
when the setpoint
is displayed
GFCI fault indicator *
GFCI fault light *
* available on certain models only
3. Installation
4. Power-up
5. Error Messages
6. GFCI Test