Aube Technologies TH110A-SP-P Thermostat User Manual


 
SUMMARY
OPTIONS SELECTION
At the back of the thermostat, there are three selection switches to set at
your preferences.
Temperature in °C or °F, time in 12 or 24 hours and Early Start function.
TO SET TIME AND DAY
Press on DAY, HOUR and MIN buttons to adjust time and day.
TO RECORD THE (COMFORT) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button. Press on
button (2 to 3 seconds) until icon appears on display.
TO RECORD THE (ECONOMY) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button.
Press on button (2 to 3 seconds) until icon appears on display .
T
O RECORD THE (VACATION) SETPOINT TEMPERATURE
To program the Vacation temperature, select the desired degree using the
buttons and press on the and buttons simultaneously
until the icon is displayed (app. 3 seconds).
OPERATING MODES
To select an operating mode, use MODE button.
AUTO: Runs the program. or shows temperature setting
and can override temporarily your programming up to the
next program.
MAN: Maintains the selected temperature. or changes
the temperature setting.
MODEL TH110A-SP-P (120 V)
u
u
u
u
u
u
INSTALLATION
PARTS INCLUDED
- One (1) TH110A-SP-P (120 VAC) thermostat
- Two (2) 6-32 screws
- Four (4) solderless connectors (for copper wire)
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat
clean and free from obstructions.
NOTE : The "Problems and Solutions" section at the end of this user's guide will
help you to correct your problems during the installation.
This thermostat has been designed to operate with any installation
which has a RESISTIVE load not exceeding 2400 W (20 A) @ 120 VAC
such as electric baseboards, radiant ceilings and floors, electric con-
vectors, etc. It is not compatible with a low voltage controller used by
a central heating system.
Electricians or experienced technicians should install the thermostat.
This thermostat is designed to be used with a self-protected heating
system equipped with thermal cut off and circuit breaker.
1) Connecting wires and mounting thermostat
Connect the rear thermostat wires to the 120 V LINE and to the load using
solderless connectors for copper wires. See schematic diagram.
Push the excess wire back into the electrical box to prevent interference with the
thermostat. Secure the thermostat using two (2) 6-32 screws. Once the
thermostat is properly installed, return power to heating system.
NOTE : All cables and connections must conform to the local electrical code.
WARNING: Special CO/ALR solderless connectors must be used when
connecting with aluminum conductors.
LOAD
120 V LINE
120 VAC
60 HZ
B
B
W
B
W
W
W
B
OLD
THERMOSTAT
LOAD
SUPPLY
BLACK
BLACK
BLACK
WHITE
BLACK
AFTER
BEFORE
Power-up
Set the On/Stand by switch to On.
When power is applied for the first time, the
display must show the time 00:00, the room
temperature and the Manual mode icon ( ).
Other information might show up on the display if
installation is defective or does not comply with the
instructions.
NOTE : The On/Stand by switch set to Stand by
will place the thermostat in sleep mode.
Ideal for summertime.
2400 W (NI) @ 120 Vca