Atlas MLG180W Indoor Furnishings User Manual


 
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Mode: On-Time Works: Day Night
Test
5 Seconds x x
Auto
1, 5, or 10 Minutes x
Manual
To Dawn* x
© 2008 Atlas Lighting Products, Inc. 598-1092-02
Models MLG180B
MLG180W
TEST
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
OPERATION
* resets to Auto Mode at dawn.
... back on.
1 Second OFF
then...
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
This package includes:
Light Control
Sensor
Cover
Plate
Bulb
Holders
Plastic Hanger
Rubber Plug
Gasket
6 Screws
(3 sizes included)
Mounting Strap
Mounting Bolt
2 Wire
Connectors
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Meets the ENERGY STAR
®
guidelines
when used with 120 W Max bulbs.
AUTO
MANUAL MODE
GUARDIAN PRO
180 SeRieS
240-026-A