Ariston Heaters Fan User Manual


 
3
General Remarks
Caution The manufacturer cannot be responsible for the damages caused by improper installation
or by failure to follow instructions in this pamphlet. Comply with the installation instructions
before completing electric connection.
Caution The thermostat has been pre-set at the factory to about 60°C/140°F. To reduce the risk of
scald injury, keep the thermostat at the
warm
position. (letter M, Fig. 3-4)
Caution Hydrogen gas can be produced in a hot water system served by this heater that has not been
used for a long period of time (generally 2 weeks or more). Hydrogen gas is extremely
flammable. To reduce the risk of injury under these conditions, it is recommended that the
hot water faucet be opened for several minutes at the kitchen sink before using any electrical
appliance connected to the hot water system. If hydrogen is present, there will probably be
an unusual sound such as air escaping through the pipe as the water begins to flow. There
should be no smoking or open flame near the open faucet at this time.
C 0,8"
E
DIMENSIONS FOR P10 S / P15 S
Installation Instructions
The P 10S and P 15S water heaters can be installed under the sink.
Wall Fasten the supplied mounting bracket to the wall. Use screws that are suitable for the wall
Mounting material and the weight of the heater.
Hang the water heater on the bracket. Tug downwards on the heater to ensure that both
"fingers" of the bracket are seated in the mounting slots.
MOD A B C D E
P10 S 14" 10 1/4" 14" 3 1/2" 6 1/8"
P15 S 14" 12 1/4" 14" 3" 6 1/8"