American Water Heater ABCG3 Water Heater User Manual


 
18
TYPE B GAS VENT
Multiple Gas Fired Tank-Type Heaters



TABLE 7. TECHNICAL DATA VENTING
MODEL BCG370T1205NOX
Input: 120,000 Btu/hr Total Vent Height (Feet)
Vent Connector Size: 5 inches
6 8 10 15 20 30 50 100
Input Btu/hr
Rise
Vent Connector Diameter (Inches)

 6 6 5 5 5 5 5 5

 5 5 5 5 5 5 5 5

 5 5 5 5 5 5 5 5
Number of
120 Heaters
Combined Input
in Thousands of Btu/hr Manifold and Common Vent Diameter (Inches)
2

7 7 6 6 6 6 6 6
3

8 8 7 7 7 6 6 6
4

9 9 9 8 8 7 7 6
MODEL
BCG380T1506NOX
Input: 154,000 Btu/hr Total Vent Height (Feet)
Vent Connector Size: 6 inches
6 8 10 15 20 30 50 100
Input Btu/hr
Rise Vent Connector Diameter (Inches)

 6 6 6 6 6 6 6 6

 6 6 6 6 6 6 6 6

 6 6 6 6 6 6 6 6
Number of
154 Heaters
Combined Input
in Thousands of Btu/hr Manifold and Common Vent Diameter (Inches)
2

7 7 6 6 6 6 6 6
3

8 8 7 7 7 6 6 6
4

9 9 9 8 8 7 7 6
MODEL BCG395, (A)BCG3100-180, 199, 200
Input: 180,000 and 199,000 Btu/hr Total Vent Height (Feet)
Vent Connector Size: 6 inches
6 8 10 15 20 30 50 100
Input Btuh/hrRise
Vent Connector Diameter (Inches)

 7 7 6 6 6 6 6 6

 7 7 7 6 6 6 6 6

 6 6 6 6 6 6 6 6

 7 7 6 6 6 6 6 6

 6 6 6 6 6 6 6 6

 6 6 6 6 6 6 6 6
Number of
Heaters
Combined Input
in Thousands of Btu/hr Manifold and Common Vent Diameter (Inches)
2

7 7 6 6 6 6 6 6

7 7 7 6 6 6 6 6
3

7 6 6 6 6 6 6 6

7 7 6 6 6 6 6 6
4

6 6 6 6 6 6 6 6

6 6 6 6 6 6 6 6
TECHNICAL DATA VENTING