American Water Heater (A)BCG38T500-8P Water Heater User Manual


 
10
Servicing should only be performed by a Quali ed Service Agent
INSTALLATION CONSIDERATIONS
Table 2
MINIMUM CLEARANCES TO COMBUSTIBLE SURFACES
“A” - Right Side “B” - Left Side “C” - Back
5” (12.7 cm) 5” (12.7 cm) 5” (12.7 cm)
A, B, and C clearances to non-combustible surfaces is “0” inches. A 20” clearance to cover remains unchanged.
CLEARANCES (EXTERIOR)
The illustration below shows the required clearances for venting units using natural draft venting.
The vent must extend at least 3 feet above the highest point where it passes through a
roof of a building and at least 2 feet higher than any portion of a building within a horizontal
distance of 10 feet (for vents of 12 inches in diameter or less).
Reference: NFPA 54 ANSI Z 223.1.