American Water Heater ABCG3 Water Heater User Manual


 
18
TYPE B GAS VENT
Multiple Gas Fired Tank-Type Heaters
When venting multiple tank type heaters using Type B vent



TABLE 7. TECHNICAL DATA VENTING
MODEL BCG370T1205NOX
Input: 120,000 Btu/hr Total Vent Height (Feet)
Vent Connector Size: 5 inches
6 8 10 15 20 30 50 100
Input Btu/hr
Rise
Vent Connector Diameter (Inches)
120,000
 6 6 5 5 5 5 5 5
120,000
 5 5 5 5 5 5 5 5
120,000
 5 5 5 5 5 5 5 5
Number of
Heaters
Combined Input
in Thousands of Btu/hr Manifold and Common Vent Diameter (Inches)
2
240,000
7 7 6 6 6 6 6 6
3
360,000
8 8 7 7 7 6 6 6
4
480,000
9 9 9 8 8 7 7 6
MODEL BCG380T1506NOX
Input: 154,000 Btu/hr Total Vent Height (Feet)
Vent Connector Size: 6 inches
6 8 10 15 20 30 50 100
Input Btu/hr
Rise Vent Connector Diameter (Inches)
154,000
 6 6 6 6 6 6 6 6
154,000
 6 6 6 6 6 6 6 6
154,000
 6 6 6 6 6 6 6 6
Number of
Heaters
Combined Input
in Thousands of Btu/hr Manifold and Common Vent Diameter (Inches)
2
308,000
7 7 6 6 6 6 6 6
3
462,000
8 8 7 7 7 6 6 6
4
616,000
9 9 9 8 8 7 7 6
MODEL BCG395, (A)BCG3100-180, 199, 200
Input: 180,000 and 199,000 Btu/hr Total Vent Height (Feet)
Vent Connector Size: 6 inches
6 8 10 15 20 30 50 100
Input Btuh/hrRise
Vent Connector Diameter (Inches)
180,000
 7 7 6 6 6 6 6 6
199,000
 7 7 7 6 6 6 6 6
180,000
 6 6 6 6 6 6 6 6
199,000
 7 7 6 6 6 6 6 6
180,000
 6 6 6 6 6 6 6 6
199,000
 6 6 6 6 6 6 6 6
Number of
Heaters
Combined Input
in Thousands of Btu/hr Manifold and Common Vent Diameter (Inches)
2
360,000
7 7 6 6 6 6 6 6
398,000
7 7 7 6 6 6 6 6
3
540,000
7 6 6 6 6 6 6 6
597,000
7 7 6 6 6 6 6 6
4
720,000
6 6 6 6 6 6 6 6
796,000
6 6 6 6 6 6 6 6