Amana AMH* Furnace User Manual


 
8
PRODUCT DESIGN
MODEL
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
ID BLOWER
PRESSURE
SWITCH
PART #
MODEL
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
ID BLOWER
PRESSURE
SWITCH
PART #
AMH80453AX**
-0.60 B1370142
AMH80453AX**
-0.60 B1370142
AMH80703AX**
-0.60 B1370142
AMH80703AX**
-0.60 B1370142
AMH80704BX**
-0.60 B1370142
AMH80704BX**
-0.47 B1370176
AMH80903BX**
-0.60 B1370142
AMH80903BX**
-0.75 B1370179
AMH80904BX**
-0.60 B1370142
AMH80904BX**
-0.75 B1370179
AMH80905CX**
-0.70 B1370158
AMH80905CX**
-0.60 B1370142
AMH81155CX**
-0.70 B1370158
AMH81155CX**
-0.70 B1370158
AMH81405DX**
-0.75 013070159
AMH81405DX**
-0.60 013070142
PRESSURE SWITCH TRIP POINTS
AND USAGE CHART
SQUARE NOSE ROUND NOSE
PRESSURE SWITCH TRIP POINTS
AND USAGE CHART
For installaions in Canada, the AMH8 furnace is certified only to 4,500 ft.
* Negative pressure readings are in inches of water column (*w.c.)
Part Number 0130F00035 20162906 20162903 0130F00036
Open Setting (°F)
220 170 160 180
AM H80453A*
1 --- --- ---
AM H80703A*
--- 1 --- ---
AMH80704B*
--- 1 --- ---
AMH80903B*
--- 1 --- ---
AMH80904B*
--- --- 1 ---
AMH80905C*
--- --- --- 1
AMH81155C*
--- --- --- 1
AMH81405D*
--- --- 1 ---
PRIMARY LIMIT
Part Number 10123529
Open Setting (°F)
300
AMH80453AX**
2
AMH80703AX**
2
AMH80704BX**
2
AMH80903BX**
2
AMH80904BX**
2
AMH80905CX**
2
AMH81155CX**
2
AMH81405DX**
2
ROLLOUT LIMIT SWITCHES
Part Number 0130F00038
Open Setting (°F)
120
AMH80453A*
1
AMH80703A*
1
AMH80704B*
1
AMH80903B*
1
AMH80904B*
1
AMH80905C*
1
AMH81155C*
1
AMH81405D*
1
AUXILIARY LIMIT SWITCHES