PAA-100F
Supplemental Regulator Unit
For RCX-88 and RCX-128 Systems that include the ALL CALL Feature
- INSTRUCTIONS -
NOTE:
Only wiring concerning the supplemental
regulator unit is shown here. For complete
installation and wiring information, please see
the complete RCX Installation instructions.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX: (425) 455-0071
The RCX-88 and RCX-128 Systems have the All Call feature as an option. This option requires
more power than the standard CEU provides. The PAA-100F Supplemental Regulator Unit
provides the necessary power to operate the system and the All Call feature. This unit replaces
the HR-10-12 power source that comes standard in the RCX-88 and RCX-128.
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
paa-100f.vsd
121997jd
INSTALLATION:
1. Locate existing HR-10-12 at the top of the RCX-88 or RCX-128.
2. Mark wires with terminal locations before disconnecting, then disconnect and remove the unit.
3. Remove the aluminum plate from the bottom of the HR-10-12 and reattach it to the bottom of the
PAA-100F. Install the new regulator unit in place of the original one.
4. Reconnect the wires to the PAA-100F in the same way that they were connected previously.
Note some of the terminal definitions are labeled slightly differently, but they have the same function.
Replace with PAA-100F and
connect as follows:
TOP OF RCX-88 or RCX-128
EXISTING:
+S
+V
-V
-S
GND
ACL
ACV
Wht
Blk
Grn
Wht
Wht
Blk
Grn
Wht
Wht
+S
+
-
-S
FG
AC
AC
Wht
Grn
Wht
Wht
Existing HR-10-12 Wiring:
TOG
CNT
NEW:
Blk
Blk
Grn
Wht
Wht
Multi-pin male connector on
right side -- solder middle
two pins together with
jumper wire.
ADD JUMPER:
Inside CEU on mother board
(rear vertical plane)
GND
Vadd
12V
Install
jumper
Connector
attached here
No Connector
attached