Aiphone MKW-DK Home Security System User Manual


 
WIRING DIAGRAM:
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
MKW-DK Instr.
0102bkjd
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
E-MAIL: tech-serv@aiphone.com
+
-
Power
Supply
1A1
1A2
L
L
+
-
Aiphone Monitor
Motion Detector*
White
Yellow
*Must be installed within
2' of door station.
Installation Guidelines:
1. The motion detector must provide a normally open momentary contact. A Photelectric beam, pressure
pad, or remote call button can also be used to activate the video door station.
2. MKW-DK must be installed within 2 feet of video door station.
3. The MKW-DK can be used to connect a motion detector to all MK, MY, KA, and KC series video door
stations.
4. The above diagram is representative of the installation of the MKW-DK to an Aiphone video system.
Terminal definitions will vary depending on the system being installed.
5. The MKW-DK is not compatible with the KB-DAR. Contact Aiphone for information on model KB-DAR-M
(KB-DAR with input for Motion Detector).
Note:
For complete system installation, please refer to the instruction manuals included with the video system.
Door Strike
PT-1210N
(AC Transformer)
MKW-
DK*
MKW-DK
Motion Detector Interface Adaptor for Video Door Stations
Special
Order
Products
The MKW-DK Adaptor allows any standard motion detector or activation device with a normally open
contact to be interfaced with any 2-wire Aiphone Video Door Station (except KB-DAR). When the
activation device is tripped, the camera will turn on, and a chime (or tone) will be heard at the inside
monitor station(s), indicating that there is some activity near the door station location.
- INSTRUCTIONS -
A1
A2
Video Door
Station
* Or any signaling
device that provides a
a normally open
momentary dry closure.
Motion Detectors with N/O Contacts:
Detection Systems DS720I
Pulnix 6612
Intellisense 8140S
Ademco 1998PI
Sentrol AP750