Agilent Technologies E4351B Water Heater User Manual


 
72 Language Dictionary
DISP:TEXT
Sends character strings to the display when the display mode is TEXT. The LCD display has the following character set:
LCD Character Set
uppercase letters
A through Z (Case-sensitive entry)
digits
0 through 9
punctuation
_ | “ $ < > + - / = ? . : ,
blank space
A display is capable of showing up to 12 characters. However, the three punctuation characters do not count toward the 12-
character limit when they are preceded by an alphanumeric character. When punctuation characters are included, then the
maximum number of characters (alphanumeric + punctuation) that can be displayed is 15. If it exceeds the display capacity,
a message will be truncated to fit and no error message will be generated. If any character in the message is not a member
of the above character set, the character will be displayed as a starburst (all 16 segments of the character are lit).
Note IEEE Standard Digital Interface for Programmable Instrumentation requires that a string be enclosed in
either single (‘) or double (") quotes.
Command Syntax DISPlay[:WINDow]:TEXT [:DATA] <STR>
Parameters (See LCD character set)
*RST Value ‘ ‘
Examples DISP:TEXT "DEFAULT_MODE"
Query Syntax DISPlay[:WINDow]:TEXT?
Returned Parameters <STR> (Last programmed text string)
Related Commands DISP DISP:MODE *RST
Measure Subsystem
Measurement commands measure the output voltage and current.
MEAS:CURR?
MEAS:VOLT?
These queries return the voltage and current measured at the Agilent SAS’s sense terminals.
Query Syntax MEASure:CURRent[:DC]?
MEASure:VOLTage[:DC]?
Parameters (None)
Default Suffix A for MEAS:CURR?
V for MEAS:VOLT?
Examples MEAS:CURR? MEAS:VOLT? MEASURE:VOLTAGE:DC? MV
Returned Parameters <NR3>