Agilent Technologies E4351B Water Heater User Manual


 
66 Language Dictionary
Command Syntax *RCL <NRf>
Parameters 0 | 1 | 2 | 3
Example *RCL 3
Query Syntax (None)
Related Commands *PSC *RST *SAV
*RST
Meaning and Type
Reset Device State
Description
This command resets the Agilent SAS to a factory-defined state as defined below. *RST also forces an ABORt command.
If Simulator or Table mode had previously been programmed, the operation of the unit returns to Fixed mode. Simulator
mode settings revert to the factory default values, and no tables are selected.
Command State
CAL:STAT OFF DISP[:WIND]:MODE NORM
CURR[:LEV][:IMM] * DISP[:WIND]:TEXT
CURR[:LEV]:TRIG * INIT:CONT OFF
CURR:MODE FIXed OUTP[:STAT] OFF
CURR:PROT MAX OUTP:PROT:DEL *
CURR:PROT[:LEV] * TRIG:SOUR BUS
CURR:PROT:STAT OFF VOLT[:LEV][:IMM] *
CURR:SAS:ISC IMAX VOLT[:LEV][:TRIG] *
CURR:SAS:IMP 0.8 X IMAX VOLT:PROT[:LEV] *
CURR:TABL:OFFS 0 VOLT:SAS:VOC VMAX
DIG:DATA 0 VOLT:SAS:VMP 0.8 X VMAX
DISP[:WIND]:STAT ON VOLT:TABL:OFFS 0
* Model-dependent value. See Table 7-3.
Command Syntax *RST
Parameters (None)
Query Syntax (None)
Related Commands *PSC *SAV
*SAV
Meaning and Type
SAVE Device State
Description
This command only applies in Fixed operating mode. It saves the present state of the Agilent SAS to the specified location
in non-volatile memory. Up to four states can be stored. Under certain conditions (see Turn-On Conditions in chapter 5),
location 0 may hold the device state that is automatically recalled at power turn-on. Simulator and Table mode states cannot
be saved by this command. The following Agilent SAS parameters are stored by *SAV:
CURR[:LEV][:IMM] OUTP[:STAT] OUTP:REL:POL
CURR:PROT:STAT OUTP:PROT:DEL VOLT[:LEV][:IMM]
DIG:DATA[:VAL] OUTP:REL[:STAT] VOLT:PROT[:LEV]