125
5K 6K
15
15
RATED VOLTS
COOLING CAPACITY
AMPS
FUSE SIZE
WALL OUTLET
RECEPTACLE AND FUSE TYPES
4
1. All wiring must comply with local and national
electrical codes and must be installed by a
licenced electrician. Once you have any
questions regarding the following instructions,
contact a licenced electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installing and operating
this unit.
3. For your safety and protection, this unit is
grounded through the power cord when
plugged into a matching wall outlet. If you are
not sure whether your wall outlet is properly
grounded, please consult a licenced
electrician.
4. The wall outlet(3-pin) must match the plug
(3-pin) on the power cord supplied with the unit.
DO NOT use plug adapters or extension cords.
See (Table 1) for receptacle and fuse information.
5. The rating plate on the unit contains electrical
and other technical data. The rating plate is located
on the right side of the unit.
If the air conditioner has a serial plate rating
of 115 volts and up to and including 7.5 amps
the unit maybe on a fuse or circuit breaker
with other devices. However, the maximum
amps of all devices on that fuse or circuit
breaker can not exceed the amps of the fuse
of circuit breaker.
If the air conditioner has a serial plate rating
of 115 volts and greater than 7.5 amps it
must have its own fuse or circuit breaker,
and no other device or unit should be
operated on the fuse or circuit breaker.
To avoid the possibility of personal injury,
disconnect the power to the unit before
installing or servicing.
Electric Shock Hazard
Electrical specifications
Table 1
!
5K including models AAW-05CR1FHUE AAW-05CM1FHUE
6K including models AAW-06CR1FHUE AAW-06CM1FHUE
Note:
Time Delay Fuse
(or circuit breaker)
Plug type